Sizing Grease Interceptors

This is a calculator for the method portrayed in Table A1.3 in Zurn's Sizing - PDI method. This method was referred to from the article Why Grease Management on the AEE articles page. An example is provided near the Calculate button here below for your convenience.
Length = inches
Width = inches
Depth = inches
Fixture filled = (fraction)
Drainage period = minutes
Flow rate = 0  

Example: A sink's dimensions are LxWxD = 120x60x30 cm, i.e. 48x24x12 inches, and its fixture filled is 0.75. For a drainage period of 2 minutes, the calculated flow rate is 22.5GPM. By referring to the table mentioned above, the required size would be "25". (selecting the size just larger since 22.5GPM is in between 20 and 25 GPM)
PS: The calculator rounds to the nearest hundredth decimal point. So if you get "0", your number is probably smaller than 0.01.